@ladyada
Resolves: #32
their main datasheet link stays updated always pointing to the latest revision. The link on the downloads section of the learn guide is that main always updated link.
I confirmed in the current revision it lists
.0042
as the resolution in a handful of places and doesn't list.0036
anywhere.I did also find an older revision of the datasheet here: https://www.sigmaelectronica.net/wp-content/uploads/2019/10/veml7700-Datasheet.pdf that does show the
.0036
value. So it seems like they indeed changed that value some time along the way.The arduino library is also using
.0036
, I can change it over there if we want to have this change